Sherwin Incorporated’s laboratory now offers annual contracts for in-use penetrant testing.
The annual contract reduces paperwork and overhead and represents a savings of nearly 20%, compared to billing for individual tests.
Schedule of In-Use Penetrant Materials Testing
|
MIL-STD-6866 |
ASTM-E-1417 |
|
Paragraph |
Frequency |
Paragraph |
Frequency |
| Penetrants |
|
|
|
|
| Fluorescent Brightness |
5.8.4.1.1 |
quarterly |
7.8.4.1 |
quarterly |
| Water Content (Method A only) |
5.8.4.1.2 |
monthly |
7.8.2.2 |
monthly |
| Removability (Method A only)* |
5.8.4.1.3 |
monthly |
7.8.4.2 |
monthly |
| Sensitivity* |
5.8.4.1.4 |
monthly |
7.8.4.3 |
weekly |
| Viscosity |
|
optional |
|
optional |
| Water Tolerance |
|
optional |
|
optional |
| Contamination/Separation* |
|
optional |
7.8.2.1 |
optional |
| Emulsifiers |
|
|
|
|
| Removability (Method B&D)* |
5.8.4.2.1 |
weekly |
7.4.4.4 |
monthly |
| Water Content (Method B) |
5.8.4.2.2 |
monthly |
7.8.2.3 |
monthly |
| Magnetic Particle Bath - ASTM E-1444 |
|
|
|
|
| Viscosity |
|
|
5.8.3 |
monthly |
| Background Fluorescence |
|
|
7.1.4.1(2) |
monthly |
*Removability, Sensitivity, and Separation are often tested locally by the user.
Sherwin Incorporated’s QC Laboratory Service Includes:
- Providing plastic bottles with labels for forwarding samples.
- QC reports mailed within three working days after receiving samples. When requested, reports will be faxed without charge.
- Immediate phone notification of discrepancies.
- Consultation concerning discrepancies to prevent reoccurrence.
- Testing of all manufacturers’ materials.
- Providing consultation, materials, equipment and other assistance to help penetrant users establish in-house testing procedures.
Contact Person:
Bob Siegel, Laboratory Director
Sherwin Incorporated
5530 Borwick Avenue
South Gate, CA 90280
Phone: 562.861.6324
|